Model 800-1-212-TP100-SERIES

MODEL 800-1-212-TP100 Series

 G.hn Access Wave-2 & gfast Performance testing solution

Introducing the World’s First Passive Gfast Local Loop Simulators for Testing Profile 106 & 212

Main Features

  • Simulation of TP100 as defined by BBF WT-285 issue 2 (Attenuation, Impedance, Group Delay)
  • Maximum Attenuation up to 70dB
  •  Bandwidth DC to 240 MHz
  •  Low Noise Floor of less than -167 dBm/Hz
  • Upgrade Program Available
  •  Support for Testing of Reverse Power Feeding
  •  Repeatable, configurable, realistic
  • Efficient Automation / Repeatable Testing
  • Ethernet Control (CLI or GUI)
  • Variety of versions, including several models designed specifically for testing BBF’s WT-380 Gfast Performance Test Plan and a version supporting BBF IR-337 Issue 2 Single-Line test cases.

  • Download

    product overview

    The Model 800-1-212-TP100 Series offers the world’s first passive local loop simulators designed for testing Gfast. This test solution provides a variety of loop lengths and increments that are perfect for repeatable and configurable G.hn Access Wave-2  & Gfast performance testing. The 800-1-212-TP100 series of products integrate with Telebyte’s G.hn Access Wave-2 & Gfast Physical Layer Testing Solutions (see separate datasheets).

    Cable Simulation

    The cable simulated is based upon TP100 which is defined in the Broadband Forum’s WT-285, Issue 2, Revision 6, Annex E, August 2018. This product simulates attenuation, impedance, and group delay.

    Reverse Power Feed

    One important feature of Gfast is the requirement for Reverse Power Feeding for the remote device from the customer’s residential gateway. The 800-1-212-TP100 has been designed to support testing of 60 VDC Short Range Reverse Powering per ETSI TS 101 548.

    Very Low Noise Floor

    Low noise levels are extremely important when the goal is maximum capacity of the local loop. Service Providers have measured background noise levels in their networks as low as -155 dBm/Hz. An active design of a local loop simulator is incapable of achieving such a low level. Conversely, Telebyte’s passive design (with a noise floor of less than -167 dBm/Hz) is ideal for Rate-Reach performance testing of Gfast.

    Product Specifications 800-1-212-tp100-SERIES

    Simulation  TP100
    -Simulates TP100 as defined in Broadband Forum’s WT-285, Issue 2, Revision 5, Annex E, June 2018
    -Simulates attenuation, impedance, group delay
     
    CAD55
    -Simulates CAD55 as defined in Broadband Forum’s WT-285, Issue 2, Revision 5, Annex A, June 2018
    -Simulates attenuation, impedance, and group delay
    Bandwidth  DC to 240 MHz 
    Average Noise Floor  -167 dBm/Hz 
    Attenuation (Insertion Loss)   -MAE < 1.0dB (2MHz to 212MHz)
    -Maximum Attenuation up to 70dB
    Impedance Complex, varies over frequency with length  
    Group Delay  Better than 5% 
       
    System Specifications  
    DC Rating  ± 60 V between Tip and Ring and 350mA 
    DPU/Modem Connection -1 CAT6A RJ45 Connector CO side of loop
    -1 CAT6A RJ45 Connector CPE side of loop
    Control 802.3 Ethernet, including high-level command set for remote control, OR a web-based Graphic User Interface (GUI)
    Power Supply 88 to 264 VAC, 50 or 60 Hz
    Dimension [4U] W 19 in x H 7 in x D 25 in (W 482 mm x H 178 mm x D 635 mm)
    Mounting options Mountable in 19” rack

    Specifications are subject to change without notice. Made in USA.

    ORDERING OPTIONs

    800-1-212-TP100-200-25* Entry Level G.hn Access Wave-2 & Gfast Single-Channel Local Loop Simulator
    Line Lengths: 25m to 200m in 25m increments
    800-1-212-TP100-400-25* G.hn Access Wave-2 & Gfast Single-Channel Local Loop Simulator
    Line Lengths: 25m to 400m in 25m increments
    800-1-212-TP100-400-25T Single-Channel Local Loop Simulator:
    TP100 for testing G.hn Access Wave-2  & Gfast: 25m to 400m in 25m increments
    TP100 for testing TR-114i3 (150m, 300m, 450m, 600m, 900m, 1050m, 1200m, 1500m, 2000m, 2500m, 3000m)
    800-1-212-TP100-600-25* G.hn Access Wave-2 & Gfast Single-Channel Local Loop Simulator
    Line Lengths: 25m to 600m in 25m increments
    800-1-212-TP100-224-1* G.hn Access Wave-2 & Gfast Single-Channel Local Loop Simulator
    Line Lengths: 25m to 224m in 1m increments
    800-1-212-TP100-424-1 G.hn Access Wave-2 & Gfast Single-Channel Local Loop Simulator
    Line Lengths: 25m to 424m in 1m increments
    Supports WT-380 & WT-476 Performance Testing
    800-1-212-TP100-424-1T Dual-Standard G.hn Access Wave-2 & Gfast Single-Channel Local Loop Simulator:
    WT-380 (424m in 1m increments) and TR-114i3 (150m, 300m, 450m, 600m, 900m, 1050m, 1200m, 1500m, 2000m, 2500m, 3000m)
    800-1-212-TP100-624-1 G.hn Access Wave-2 & Gfast Single-Channel Local Loop Simulator
    Line Lengths: 25m to 624m in 1m increments
    Supports WT-380 & WT-476 Performance Testing
    00-1-212-TP100-424-1C Multi-Wire Type G.hn Access Wave-2 & Gfast Single-Channel Local Loop Simulator
    TP100 (25-424m in 1m increments) and CAD55 (20m, 50m, 100m, 200m, 300m, 400m)
    Supports WT-380 Performance Testing Supports IR-337 Issue 2 Single-Line Testing
    800-1-212-TP100-624-1C Multi-Wire Type G.hn Access Wave-2 & Gfast Single-Channel Local Loop Simulator:
    TP100 (25-624m in 1m increments) and CAD55 (20m, 50m, 100m, 200m, 300m, 400m)
    Supports WT-380 & WT-476 Performance Testing

    *NOTE: This model does not support WT-380