Model 458-LM-A2-36
Local Loop
Simulator
0315-0354 Rev.A
Date of Publication: 10/31/05

Customer Support
Thank you for your purchase of the Telebyte Model
458-LM-A2-36 Local Loop Simulator, featuring two channels that simulate 24 and
26 AWG PIC as specified in T1.417.
Contact
Information:
Telephone
E-mail/Internet
General:
631-423-3232
support@telebytebroadband.com
Technical
support:
800-835-3298
sales@telebytebroadband.com
Fax:
631-385-8184
www.telebytebroadband.com
Mail
Telebyte, Inc.
355 Marcus Blvd
Hauppauge, NY 11788
Warranty
|
Included With
Your Purchase |
|
One-year
Warranty • Telebyte will furnish parts and
labor for the repair or replacement of products found by Telebyte to be
defective in material or workmanship during the warranty period.1
One-year Calibration
(where applicable)
• One N.I.S.T. traceable
calibration on the first-year anniversary of the product ship date.2
• Calibration report to
ensure traceability.
|
|
Extended Customer
Care |
|
There
are two options available. Our three-year extended warranty extends the
original warranty by an additional 36 months and the three-year calibration
contract provides 36 additional months of calibration.
|
|
Three-Year
Extended Warranty You can extend the original
one-year warranty that comes with your product by purchasing the Three-Year
Extended Warranty.3
Features:
·
Telebyte will
furnish parts and labor for the repair or replacement of products found by
Telebyte to be defective in material or workmanship during the warranty
period.1
|
Three-Year
Calibration Contract (where applicable) Extended calibration
is available through the Three-Year Calibration Contract.4
Features:
· Yearly N.I.S.T. traceable
calibrations, each on the second, third and fourth anniversary of the ship
date.2
·
Report to ensure
traceability.
·
Automatic
notification when calibration of your product is due.
|
|
Disclaimer of Warranties and Other
Terms and Conditions |
|
1 TELEBYTE, INC. warrants its
broadband simulation equipment to be free from defects in material and
workmanship, under normal and proper use and in its unmodified condition, for
12-months, starting on the date it is delivered for use. TELEBYTE’S sole
obligation under this warranty shall be to furnish parts and labor for the
repair or replacement of products found by TELEBYTE to be defective in
material or workmanship during the warranty period. Warranty repairs will be
performed at the point of manufacture. Equipment approved for return for
warranty service shall be returned F.O.B. TELEBYTE factory and will be
redelivered by TELEBYTE freight prepaid, except for non-continental U.S.A.
locations. These deliveries will be sent COD freight and import/export
charges.
2 The
customer is responsible for freight and customs charges when shipping
products to and from Telebyte for calibration services.
3 You
must purchase the extended warranty at the time of purchase or during the
initial warranty period.
4 You must
purchase the calibration contract at the time of purchase or during the
initial warranty period. The above warranty is in lieu of all other warranties, expressed
or implied, statutory or otherwise, including any implied warranty of
merchantability or fitness for a particular purpose. TELEBYTE shall not be
liable for any damages sustained by reseller or any other party arising from
or relating to any equipment failure, including but not limited to
consequential damages, nor shall TELEBYTE have any liability for delays in
replacement or repair of equipment.
|
Equipment Returns
Out of warranty equipment may be returned, prepaid, to the Greenlawn, N.Y. customer service facility. Return shipping
charges will be billed to the customer. The repaired unit will have a 90-day
warranty. In those cases where "no trouble" is found, a reduced
charge will be billed to cover handling, testing, and packaging. Whether in or
out of warranty, a Return Material Authorization number (RMA) is required and
may be obtained by:
Calling customer service at 631-423-3232 or 800-835-3298
Sending a request via Fax at 631-385-8184
E-mailing us at support@telebytebroadband.com
Please be sure to reference the RMA number on the outside
container.
Table of Contents
1.0
Introduction.........................................................................................................................
1-1
2.0 Specifications......................................................................................................................
2-1
2.1
458-LM-A2-36................................................................................................................
2-1
2.2
458-2SL........................................................................................................................
2-2
2.3
458-CM.........................................................................................................................
2-3
3.0
Connections........................................................................................................................
3-1
3.1
458-LM-A2-36................................................................................................................
3-1
3.2
458-2SL/458-CM............................................................................................................
3-2
3.2.2 Connections 458-CM/458-2SL IEEE488
Control............................................................ 3-3
4.0
Control................................................................................................................................
4-1
4.1.1 RS-232 (Serial Port)
Remote Commands.......................................................................
4-1
4.1.2
IEEE 488 (GPIB) Remote
Commands..........................................................................
4-4
4.2
Graphical User
Interface.................................................................................................
4-8
4.3 LCD Display
(458-2SL)...................................................................................................
4-9
1.0 Introduction
The Model 458-LM-A2-36 Local Loop Simulator simulates 24 and 26
AWG PIC as specified in T1.417. This plug and play line module provides two
channels with loop lengths from 0 to 3,150 ft, in 50-ft increments.
Other features include:
- Bandwidth to 36 MHz
- Accurately simulates attenuation and impedance
- Two channels per line module (one 24 and one 26 AWG)
- Plugs into our 458-CC (16-slot chassis) or 458-2SL
(2-slot chassis)
- Independent control of each channel
- Ability to open loop at either end of any channel
- MAE <1 dB

Figure
1: Front View of Model 458-LM-A2-36. Both the front and rear of the line module
have 4 RJ-45 connectors.
2.0 Specifications
2.1 458-LM-A2-36
|
Product
Specifications - Model 458-LM-A2-36
|
Features
|
·
Accurately
simulates attenuation and impedance
·
Full bi-directional
operation at all specified frequencies
|
Bandwidth
|
· DC to 36 MHz
|
Attenuation Accuracy
|
· MAE < 1 dB (when source and
load impedances are 100 ohms)
25 kHz to 36 MHz
|
Maximum Attenuation
|
> 90 dB
|
Impedance
Accuracy
|
Typically +/- 10% 25 kHz to
36 MHz
|
Maximum Voltage Tip
–Ring
|
200 V
|
Maximum
Current
|
130 mA
|
|
Connectors
|
4 RJ-45’s on front including 2 for noise injection. 4
RJ-45’s on back including two for noise injection.
|
2.2 458-2SL
|
Product Specifications – Model 458-2SL
|
Switches
|
Two
rotary encoders (one per channel) located on front of control module.
Push-button switch for setting IEEE 488 address or RS-232 communication
parameters.
|
Indicators
|
Backlit
LCD display of line length and set up parameters.
|
Power
|
100 -
250 VAC, 50 or 60 Hz (universal power supply)
|
Size
|
[2U] 19
in W x 22 in D x 3.47 in H (482.6 mm W x 558.8 mm D x 88.1 mm H)
|
Environmental
|
Operating
temperature: 0 to 50 degrees C, humidity: 0 to 95% relative humidity
(non-condensing).
|
Remote Control
Connectors
|
RS-232:
DB9 female (DCE); GPIB:IEEE488 24-pin connector.
|
User Command Interface
|
ASCII command
set compliant with IEEE 488.2 and Hex ASCII two-character bytes per 488 bus
data byte. RS-232: HDX (Echo characters); Translate CR to CR + LF; baud rate:
300 to 19200; commands use terminating character (carriage return); 8 Data
bits; 1 stop bit.
|
2.3 458-CM
|
Product Specifications – Model 458-CM
|
Switches
|
Power
on/off. Eight-position dip switch located on the Control Module for setting
IEEE 488 address or RS-232 communication parameters.
|
Indicators
|
Two LED’s
on Control Module indicating power-on and communication error.
|
Power
|
100,
110 or 220 VAC
|
Size
|
[7U] 19
in W x 22 in D x 12.22 in H
(482.6
mm W x 558.8 mm D x 310.4 mm H)
|
Environmental
|
Operating
temperature: 0 to + 500 C, Humidity: 0 to 95% relative humidity
(non-condensing).
|
Remote Control
Connectors
|
RS-232:
DB9 female (DCE); GPIB:IEEE488 24-pin connector.
|
User Command Interface
|
ASCII
command set compliant with IEEE 488.2 and Hex ASCII two-character bytes per 488
bus data byte. RS-232: HDX (Echo characters); Translate CR to CR + LF; baud
rate: 300 to 19200; commands use terminating character (carriage return); 8
Data bits; 1 stop bit.
|
Specifications are
subject to change without notice. Made in USA.
3.0 Connections
3.1 458-LM-A2-36
The input and output ports are interchangeable (i.e., the
unit is bidirectional). The cable pair is accessible through the RJ-45 jacks on
the front and rear of the line module. The two center contacts, Tip and Ring
(pins 4 and 5), of each RJ-45 are supported. Refer to Figure 2 for the
configuration of the RJ-45 jack.
i
Do not exceed the maximum ratings as listed in section 2.0, “Specifications.”
For best accuracy, the I/O cables should be limited to 3 m or less.

Figure 2: RJ-45
Configuration

Figure 3: RJ-45
Configuration
3.2 458-2SL/458-CM
3.2.1 Connections 458-CM/458-2SL - RS232 Control
A “straight-through” serial cable (not a “crossover”) is used
to connect the RS-232 control unit to the Telebyte chassis. The Model 458-CM(-2SL) is completely controllable from an RS-232 source.
The following section explains the connections and the controls necessary for
RS-232 operation. See Figure 4 for an illustration of the pin connectors

Figure 4 DB-9 for RS-232
Control
Pin 2 on the Model 458-CM(-2SL)
connects to the RECEIVED DATA pin in the Communications Port Connector on the
PC or controller.
Pin 3 on the Model 458-CM(-2SL)
connects to the TRANSMIT DATA pin in the Communications Port Connector on the
PC or controller.
Pin 5 on the Model 458-CM(-2SL)
connects to the GROUND pin in the Communications Port Connector on the PC or
controller.
Pins 6 and 8 are connected together and held at a positive
voltage.
Common Communications Port Connectors, such as those found on
PCs, are DB-9 and DB-25. The standard pin assignments for these connectors are
as follows:
|
|
DB-9
|
DB-25
|
Direction
|
|
Received
Data
|
2
|
3
|
Serial
Data from Model 458-2SL
|
|
Transmitted
Data
|
3
|
2
|
Serial
Data to Model 458-2SL
|
|
Ground
|
5
|
7
|
Common
Ground
|
|
CTS
|
8
|
5
|
+
Voltage Out
|
|
DSR
|
6
|
6
|
+
Voltage Out
|
The remaining pins are not connected to the Model 458-CM(-2SL).
User Command Interface
RS-232 - LF, Baud rate 300 to 19200, commands use terminating
character (Carriage Return), eight Data Bits, one Stop Bit.
3.2.2 Connections 458-CM/458-2SL
IEEE488 Control
The Model 458-CM(-2SL) is completely
controllable from an IEEE 488.1 (488.2) source. The following section explains
the connections and controls necessary for IEEE operation.
ASCII command set compliant with IEEE 488.2 and in Hex ASCII
two-character bytes per 488 bus data byte.

Figure 3 IEEE 24-pin Connector
Connect a standard IEEE cable from the Model 458-CM(-2SL) to the IEEE General Purpose Interface Bus
controller.
User Command Interface
The Model 458-CM(-2SL) is intended
to be operated from an IEEE Controller such as a PC equipped with an IEEE
interface board. The set up of your computer and IEEE controller board may be
different depending on the manufacturer of your equipment. Follow the set up
instructions supplied with your equipment.
4.0 Control
The Model 458-LM-A2-36 can be controlled three ways: Via
RS-232 and IEEE488 Remote Commands, our GUI interface or the LCD display on the
front panel of our 458-2SL.
4.1 Remote Commands
4.1.1 RS-232 (Serial Port)
Remote Commands
md
Disable manual control
disable manual setting of lengths or
configuration (used in 458-2SL only)
me
Enable manual control
enable manual setting of lengths or
configuration (used in 458-2SL only)
id
Identify model no. and rev.
read model no. and software revision
code
re
Read last error
read description of last error
ee
Echo enable
echo all inputs and format output for
terminal display
ed
Echo disable
inputs not echoed and format output for
user control program
h
Help RS232 command list
read RS232 command list
cs:BR
Configure serial
where BR = 300, 600, 1200, 2400,
4800, 9600 or 19200
cp:ADD
Configure
488
where ADD = 1, 2, ... 29,
30 (No leading zeroes used)
Set Length command
sl:LM:H:LE,C
where:
LM = Module slot number à 01 - 02 or 01 – 16.
H =
Channel number à 1 – 2 (A = all
channels 1-2, Ch1 = 26 AWG, Ch2 = 24 AWG)
LE = Length 0 – 3150 in steps of
50
C =
Connect mode:
N =
connect both CO and CPE ends
P =
connect CPE only CO is open
O =
connect CO only CPE is open
Z = open
both CO and CPE ends
Example: SL:01:1:2000,N
sets channel 1 to 2000 ft for a line module in slot 1.
The connect mode is there for
those customers who would like to create an “open loop” condition at either the
CO or CPE ends, or both.
Set
all channels on all boards in the system command
sl:all:LE,C
Example: sl:all:2000,n sets
all channels in the system to 2000 ft
Set all channels on a range
of boards command
sl:LM-LM:LE,C
Example: sl:01-03:2000,n sets all channels on boards 1, 2, and 3 to
2000 ft
Set all channels on one
board command
sl:LM:a:LE,C
Example: sl:01:a:2000,n sets all channels on the board in slot 1 to
2000 ft
Read Length command
rl:LM:H
Example: rl:01:1 reports the length of channel 1 on the board in slot
1.
Read the Lengths of all
channels on one board command
rl:LM:a
Example: rl:01:a reports the lengths of all channels on the board in
slot 1.
Read the lengths of all
channels on all boards command
rl:all
Example: rl:all reports the lengths of all channels on all
boards
Read the serial number of
one line module command
rs:LM
Read the serial numbers of
all cards command
rs:all
4.1.2 IEEE 488 (GPIB)
Remote Commands
:manual:disable
Disable manual control
disable manual setting of lengths or configuration
:manual:enable
Enable manual control
enable manual setting of lengths or configuration
:lasterror
Read last error
read description of last error
*idn?
Identify model no. and rev.
read model no. and software revision code
*esr?
Event Status Register read
read IEEE esr
*sre?
Status Request Enable read
read IEEE sre
*stb?
Status Byte register read
read IEEE stb
*ese?
Enable Status Event read
read IEEE ese
*sre xx
Status Request Enable write
write IEEE sre xx
*ese xx
Enable Status Event write
write IEEE ese
:cs:BR
Configure serial
where BR = 300, 600, 1200, 2400, 4800, 9600 or 19200
:cp:ADD
Configure
488
where ADD = 1, 2, ... 29,
30 (No leading zeroes used)
Notes: All Set card lengths, English/Metric mode and Echo
enable/disable are maintained during power off in both RS-232 and IEEE modes.
Manual control is enabled at power on.
|
*SRExx
|
Enables
Status Bits as defined by the numerical value of the bits following the
command.
|
|
*SRE?
|
Used
to read the Enabling Bits in the Status Register.
|
|
*STB?
|
Reads
the Status Register
|
|
*ESExx
|
Enables
Event Status Bits as defined by the numerical value of the bits following the
command.
|
|
*ESE?
|
Used
to read the Enabling Bits in the Event Status Enable Register.
|
|
*ESR?
|
Reads
the Event Status Enable Register.
|
Status
Byte Register
|
|
Bit
|
Value
|
Set
|
Operation
|
|
0
|
1
|
0
|
Not
Supported
|
|
1
|
2
|
0
|
Not
Supported
|
|
2
|
4
|
0
|
Not
Supported
|
|
3
|
8
|
0
|
Not
Supported
|
|
4
|
16
|
1
|
Enable
Message Available bit (MAV)
|
|
5
|
32
|
1
|
Enable
Event Status Bit (ESB)
|
|
6
|
64
|
1
|
MSS
this bit is always enabled
|
|
7
|
128
|
0
|
Not
Supported
|
|
Event
Status Enable Register
|
|
Bit
|
Value
|
Set
|
Operation
|
|
0
|
1
|
1
|
Operation
Complete
|
|
1
|
2
|
0
|
Not
Supported
|
|
2
|
4
|
1
|
Query
Error
|
|
3
|
8
|
0
|
Not
Supported
|
|
4
|
16
|
1
|
Execution
Error
|
|
5
|
32
|
1
|
Command
Error
|
|
6
|
64
|
0
|
Not
Supported
|
|
7
|
128
|
1
|
Power
On
|
Set Length command
:setcard:length:LM:H:LE,C
where:
LM = Module slot number à 01 - 02 or 01 – 16.
H =
Channel number à 1 - 2
LE = Length
C =
Connect mode:
N =
connect both CO and CPE ends
P =
connect CPE only CO is open
O =
connect CO only CPE is open
Z = open
both CO and CPE ends
Example:
:setcard:length:01:1:2000,n sets channel 1 of the line module in slot 1
to 2000 ft
Set all channels on all
boards in the system command
:setcard:length:all:LE,C
Example:
:setcard:length:all:2000,n sets all channels on
all boards to 2000 ft
Set
all channels on a range of boards command
:setcard:length:LM-LM:LE,C
Example:
:setcard:length:01-03:2000,n sets boards 1, 2 and 3 to 2000 ft
Set all channels on one
board command
:setcard:length:LM:a:LE,C
Example: :setcard:length:1:a:2000,n
sets all channels on the board in slot 1 to 2000 ft
Read Length command
:readcard:length:LM:H
Example:
:readcard:length:01:1
Read the lengths of all
channels on one board command
:readcard:length:LM:a
Example:
:readcard:length:01:a
Read the lengths of all
channels on all boards command
:readcard:length:all
Read serial number of one
line module command
:readcard:sn:LM
Read all serial numbers
command
:readcard:sn:all
4.2 Graphical User Interface
The 458-LM-A2-36 Graphical User Interface (GUI) can be used
to control the Model 458-LM-A2-36. The following are brief instructions for
working with the GUI using a typical set up.

Set Control Module Parameters: Suggested
Settings:
Serial/GPIB: Serial
Com Port/Address: 1
Baud Rate: 19200
HDx Slot: 1
CH1(26 AWG) Distance: as desired
CH2(26 AWG) Distance: as desired
Set Loop
Click Set Loop to send settings.
4.3 LCD Display (458-2SL)
Top encoder selects module number and channel.
Bottom encoder selects length.
Top display line shows module number and channel.
Bottom display line shows line length and connect mode.
The Config button is used to access
a second menu on the front panel. The bottom of the LCD will display the
Communication settings used. The bottom knob on the 458-2SL will adjust this
value between GPIB address 1 - GPIB address 30 as well as RS-232 baud rates
19200,9600,4800,2400,1200 and 600.
Allowable lengths (feet)
All Channels: 0 to 3,150 ft in 50-ft increments.
Example: Manual Control of the 458-LM-A2-36 with
our Model 458-2SL chassis
Front of Model 458-2SL, with 458-LM-A2-36
Installed

Instructions
1. Turn on
power. The LCD displays “Model 458-2SL,” the current revision of the software
and then the board, channel, line length and connect mode.
2. Rotary
encoder 1 will increment the channel number for the current board and, when it
reaches the final channel, display the next board number.
3. Rotary
encoder 2 will increment the allowable line length for a given board:channel combination. The
connect mode displays automatically.